Welcome to PowerSPRAY Support

If you don’t see what you are looking for contact us! We have a team of dedicated customer service techs ready to help out.

Please send us an email or give us a call at 612-333-3189 (Toll Free: 1-866-335-2826)

Sprayer FAQs

What is the recommended pressure for the trailer tires?

30 PSI is the recommended tire pressure rating.

How do I adjust the spraying pressure or spray pattern on my Spot Sprayer?

To adjust the pressure and spray pattern on your spray gun simply rotate the adjustable spray tip. Be careful to avoid a pulsating stream (also know as cycling) as this can cause wear on your pump. See cycling section of the FAQ’s below.

How do I adjust the spraying pressure on my boom nozzles?

To adjust the pressure simply adjust the bypass valve located on your manifold. Be careful to avoid a pulsating stream (also know as cycling) as this can cause wear on your pump. See cycling section of the FAQ’s below.

Why does the fuse blow on my sprayer system?

The inline fuse can blow if the amperage being pulled by the pump is more than 15 Amps. The main reasons for this happening is:

  • System restriction. Open your return to tank valve or adjust your wand spray pattern.
  • Clogged inlet strainer causing restriction.
  • Clogged or kinked hose.
  • Defective pressure switch or motor (Call 1-866-335-2826)
  • Defective Wire Harness (call 1-866-2826)

What type of chemicals can I spray?

All Delavan Pumps can be used with most herbicides, insecticides, pesticides and other chemicals. The “Extreme Duty” are built with Geolast diaphragm’s and exhibit enhanced oil-resistance and low oil swell making it ideal for oil based applications as well as all herbicides, insecticides and pesticides. Always check with chemical manufacturer for compatibility and always follow state and federal laws.

What types of chemicals can I NOT Spray?

Do not spray with flammable liquids. Do not use corrosive liquids. These types of chemicals can lead to dangerous results or weaken the pump parts. Using these liquids void the warranty. Always check with chemical manufacturer for compatibility and always follow state and federal laws.

How do I winterize my Sprayer?

If you will be storing your sprayer for an extended period over the winter months, PowerSPRAY Sprayers recommends;

  • Keep your unit in a temperature-controlled environment.
  • Add one gallon of anti-freeze to your tank.
  • Point your spray wand back into your tank and spray. This should coat all your lines in antifreeze for storage.
  • Drain the antifreeze from your tank back into your container to be used again next winter.

Can my sprayer be used for the use of potable liquids?

The sprayer is not rated for drinking/potable liquids.

What is the warranty on my sprayer and pump?

Sprayer, pumps and all components have a two-year warranty. Please see user manual for warranty details. If you wish to use your warranty, please call 1-866-335-2826 and have your Proof of Purchase and Model Number available. Please refer to your user manual for the part number of any replacement parts you may need.

What voids a warranty on a sprayer?

Please read the warranty terms and conditions in your user’s manual for a full description of warrantable and non-warrantable conditions. Using corrosive, flammable and incompatible chemicals voids warranty. User damage and use outside regular working conditions will void warranty. Allowing your sprayer to freeze without winterizing voids warranty.

Why does my sprayer have no power/not turn on?

There are a few reasons why your sprayer may not have power. The best way to locate the issue is to use a multimeter and follow the path of electricity from battery to pump to locate the issue. Some causes and solutions could be:

  • Battery not fully charged.
  • Power switch not in the “on” position.
  • Check all electrical connections are secure.
  • Check inline fuse located on wiring harness.
  • Check power at pump.
  • Check pressure switch on pump (See ESR-008)

My sprayer is having issues priming (suction).

  • If your sprayer is having issues priming or sucking up water first check the inlet strainer for clogs or debris. If your inlet strainer is not attached, you will have to check all your hoses for debris.
  • Your pump valves may have been damaged. To perform a valve test see ESR-002.

My pump does not turn off when not spraying.

There are a few possibilities of why your pump may not be turning off. First check all hoses for leaks. Another issue could be a failed pressure switch. See ESR-008 for pressure switch testing procedure.

How do you force prime a sprayer?

If your sprayer is not priming a temporary solution is to “force prime” your pump. Remove the inlet strainer from your suction line. With a garden hose force water into your suction hose and then turn on your pump. Turn off pump and put the strainer on the hose and place back in tank.

Why does my system have low pressure?

There are a few reasons your system is putting out low pressure. Check these components for function:

  • Worn spray gun nozzle – Replace spray gun.
  • Worn boom nozzles – Replace Boom nozzle.
  • Worn Pressure Switch – Replace pressure switch assembly.
  • Inlet/Outlet Tube Restriction – Remove restriction.
  • Incorrect Voltage – Check voltage and verify within range ±10%.
  • Clogged Intake Tube – Remove obstruction from the tube.
  • Inlet Air Leak – Tighten loose fittings, replace cracked fittings.
  • Worn Diaphragm – Replace the diaphragm assembly.

Why is my pump leaking?

  • Check fasteners between pump head and motor. Tighten if necessary.
  • Torn diaphragm. Replace lower housing assembly of pump.

Why does my spray gun or nozzles have an inconsistent spray pattern?

Often this is caused by a clogged suction strainer or intake tube. Also check spray gun components and replace if necessary.

Diaphragm Pump FAQs

My pump does not turn on.

  1. Check for power (Supply voltage +/- 10%)
  2. Check pressure switch. Please see ESR-008.
  3. Check relay – It will make a click sound if failed. (FB2/FB3 series demand pump)
  4. Replace motor

My pump is not flowing.

  1. Check valve. Please see ESR-002.
  2. Check for inlet leak like a broken hose, fitting or loose hose clamp preventing the pump from priming. May need a new pump head. Please see ESR-003.
  3. If the pump is still not flowing, replace the lower housing and/or valve plate. Please see ESR-003.

My pump is not shutting off or does not build pressure.

  1. Check for correct voltage (Supply voltage +/- 10%)
  2. Check for system debris, leaks, trapped air.
  3. Check for low flow. Replace the Lower Housing Assembly. Please see ESR-003.
  4. Check for pump head leaks (tighten screws or new pump head)
  5. Adjust pressure switch. Please see ESR-001.

My pump is turning on and off quickly (Cycling).

Pump ‘cycling’ is when the pressure switch of any demand style pump is rapidly turning on and off. Understanding why your pump is doing this is essential to finding a solution to the issue.

  • Understanding Pressure Switches

To understand why your pump is cycling it is important to understand how a pressure switch works.  On the top of all demand style pumps there is a pressure switch. Inside the pressure switch is a small diaphragm connected to an electrical On/Off switch. Once the pressure in the pump head reaches a certain pre-set limit (ex. 60 psi) the diaphragm will inflate and hit the electrical On/Off switch turning your pump off. Once the pressure in the pump goes below the pre-set limit (ex. 60 psi) the diaphragm will deflate turning the pump back on.

  • Flow vs. Restriction

The flow of your Delavan Pump and your system’s restrictions are the next factors to consider. The flow of your Delavan Pump is written on the label of your pump. For this example, you have a 5 GPM Delavan pump and have it hooked up to nozzles or a spray wand. The nozzle or wand is only able to put 2 GPM, this is the restriction of your system. Your pump always wants to push 5 GPM but the system restriction won’t allow it. This causes your pump’s pressure switch to rapidly turn On/Off. Much like any electrical system, turning your pump On/Off rapidly is causing damage and may cause your pump to prematurely break down.

  • How do I stop my pump from cycling?

Recognize what is causing the restriction. It could be the size of your nozzles, the wand you are using, a kinked hose in your system, the diameter of the hose, too many 90º fittings. It can be one or a few of these issues. Fixing the restriction and increasing the flow of your system will stop cycling.

If you are using a Sprayer or Wand type system you can easily add a return to tank or “bypass” which will circulate any extra fluid back to the tank. Do this by adding a T-fitting and valve just past the outlet and a hose which will direct any excess flow back to the tank.  We have a Youtube video explaining this; https://www.youtube.com/watch?v=QEN6AXZrAGM

Finally, you can adjust the pressure of where your pressure switch will turn off power to your pump by adjusting the set-screw on top. Follow this link for an explanation of how to do that. Please see ESR-001.

My pump leaks.

    1. Check for loose screws at switch or pump head.
    2. Check the switch diaphragm ruptured or pinched. Replace the pressure switch. Please see ESR-008.
    3. Check for fluid in the pump head. If present, replace the lower housing assembly. Please see ESR-003.
    4. If you have a 7822FS serial number and the pump is leaking from the Flex-Ports please see Please see ESR-027.

   or this youtube video. https://youtu.be/jVeK0pmCcdo

Why does my pump get very hot?

Delavan pumps are equipped with high torque continuous duty cycle motors. They are designed to run continuously at pressures less than 50-60 PSI.
If the motor is getting hot, typically the pressure is high causing the motor to work harder.

Solutions:
1. Reduce the operating pressure to 30-40 PSI

2. If pressures higher than 50-60 PSI are required, introduce a duty cycle, use the pump for 50 minutes and then let it rest for 10 minutes to allow the motor to cool down.

Fittings List

MODEL STANDARD AVAILABLE OPTION
5800 1/2″ NPT
5900 3/4″ Quick Attach
7800 5/8″ Quick Attach 3/8″ NPT
7800 FLEX 3/4″ Quick Attach 5/8″ Quick Attach (Needs QA Adapter FA-7822FS)
7870/7871 FB 1/2″ NPT
7970 3/4″ Quick Attach

Import vs Domestic Pump

Any pump with an ‘-I’ at the end of the model number is an import pump. The upper housing assembly and valve plater are not replaceable with a standard domestic pump. Pressure switches are interchangeable on all models and so are lower housing assemblies.

Demand vs Bypass

A demand pump shuts off at pressure setting. You can identify a demand pump by the wire leads out of the pump head (pressure switch). A bypass pump runs continuously when it has power. You can identify a bypass pump since they only have 2 wires out of the motor.

Are Delavan diaphragm pumps self priming? Can they run dry?

Diaphragm pumps self prime and can run dry.

Which models are potable water safe (NSF)?

All models are NSF certified except import and FB3 (7871/7971) series pumps.

Fuse/Wire Size

Chemical Compatibility

Please contact Delavan Technical Support to discuss your application.

Can I adjust my pressure switch?

Adjusting the pressure switch may increase pump wear and tear which therefore reduces pump life.

What does Extreme Duty mean?

Extreme Duty pumps are made with stronger and heavier duty Geolast diaphragms. Pumps with Geolast diaphragm exhibits enhanced oil-resistance and low oil swell making it ideal for oil based applications. Geolast provides moderate flex life and good abrasion resistance over a wide temperature. Should not be used with gasoline.

Can I pump diesel through my pump?

Never pump gasoline, flammable liquids or combustible liquids. Pumps with santoprene diaphragms are designed for use with water-based products only. Pumps with Extreme Diaphragm (ED) designation are made with Geolast Diaphragms and are compatible with non-flammable and non-combustible oil-based liquids.

Can I pump bleach through my pump?

Yes, you can pump bleach through any Delavan PowerFLO Pump.

Sodium hypochlorite or bleach is a key component in thousands of production and disinfection processes in a variety of industries. Though testing we have found that sodium hypochlorite does affect the elastomers (or elasticity) of the pumps diaphragm over time. Simply put, a pumps diaphragm is similar to an elastic band and continuous use over time with bleach will cause it to dry out and have less elasticity.

There are steps you can take to prolong the life of a diaphragm pump used in conjunction with bleach.
1. Flush out you pump after each use with fresh water for 90 Seconds
2. Dilute the bleach. Delavan recommends a concentration of 12%. (Similar to the concentration used in most soft wash applications)
3. Replace the pump’s diaphragm every 12-18 months (depending on usage) or when you begin to see a significant drop in flow.

What size pump should I use for my application?

In order to optimize the performance and life of your Delavan Fluid Power pump we recommend matching your systems output GPM as close as possible to the pumps GPM. For example if you have a four nozzle boom and each nozzle puts out 0.5GPM at 40PSI, you would want a pump close to 2.0GPM.

If you are replacing a pump on a sprayer system try to match as close as possible the GPM of the pump you are replacing. Moving to a larger pump with a higher GPM output will cause the pump to cycle therefore reducing the life of the diaphragm and pressure switch.

For help on deciding which pump is best for you, please call 1-866-DELAVAN and one of our representatives will be happy to help you.

Why does the relay on my FB Pump need to be replaced?

Your FB Pump is always trying to pump 7 GPM from the inlet to the outlet. When either side of your pump has a restriction, the pump begins ‘working harder’ to get the desired 7 GPM output. When asked to ‘work harder’ it is drawing more AMPS from your electrical source to get more power. With enough system restriction it can cause an AMP spike which in turn can burn out your relay. (Your relay is actually working as a fail-safe here protecting your pump from further damage.)

What is restriction?

Restriction, as far as your pumps set-up is concerned, is anything that prevents your pump from pumping 7 GPM. This can be improper nozzle sizes, hose diameter too small, 90° fittings, kinks in hoses, etc.
If you can decrease the restriction, you can decrease the probability of this happening again.

Plumbing in a ‘Return To Tank’ to divert extra flow back to your tank is the best and easiest way to prevent premature failure of your Delavan Pump. After your pump’s outlet install a Tee fitting with a ball valve and run the hose back to your tank. By opening that ball valve, you can now divert any extra flow back to your tank.

The gauge of wire used on your pump set-up can also be considered restriction for your electrical system. Always be sure to use 12AWG wiring with your FB Pump.

Instructional Videos

Testing and Replacing a Pressure Switch

What is Pump Cycling and How to Fix It

Pump Maintenance, Assembly and Repair

Support Resources

External Support Resource List

Name Title Issue Date Rev
ESR-001 ADJUST PUMP PRESSURE 2018‑12‑05 1
ESR-002 TEST VALVE FUNCTION 2018‑12‑04 1
ESR-003 REPLACE THE UPPER OR LOWER HOUSING ASSEMBLY 2018‑12‑05 1
ESR-004 FLEX PORT INSTRUCTION 2018‑12‑05 1
ESR-007 REPLACE THE COMPLETE PUMP HEAD ASSEMBLY 2018‑12‑11 1
ESR-008 TEST PRESSURE SWITCH 2018‑12‑05 1
ESR-030 SMARTFLO – REPLACEMENT PUMP HEAD INSTRUCTIONS 2021-05-05 1